Photocells and Photoelectric sensors
Mute signalling photocell Type 109-016 - Polarised retro reflective photocell kit
The polarised retro-reflective photocell can be used in conjunction with MFU 011-155 to provide the mute initiating signals.
A safety light curtain with mute control function is often used in the packaging industry. In conjunction with a 1000 Plus Series light curtain and a MFU 011-155 two photocells are positioned to scan across a conveyor, to detect loaded pallets prior to the load interrupting the light curtain.
The photocell must be positioned to detect the load during the entire time the load is passing through the light curtain.
Type 109-016 photocell has a maximum sensing range of 3 metres. Each photocell comes complete with mounting bracket and retro-reflective mirror.
Mute signalling photocell Type 109-016
Sensing Distance | 3m |
---|---|
Transmitter Diode | Red Light |
Sensing Adjustment | Trimmer |
Protection Rating | IP65 |
Operating Voltage | 12-240V dc, 50/60Hz |
Output | Relay |
Current Consumption | 2VA max |
Response Time | 15ms |
Enclosure | Intensive ABS |
Cable | 1.5m length |
Operating Temp | -20°C to +60°C |
Humidity | 35% to 85% |
Weight | 145g |
Note: Each kit contains 1 x photocell, 1 x reflector mirror, 1 x mounting bracket.
Through-beam photocell kit - Mute signalling photocell Type 109-006
The through-beam infra-red photocell can be used in conjunction with MFU 011-155 to provide the mute initiating signals.
A safety light curtain with mute control function is often used in the packaging industry. In conjunction with a 1000 Plus Series light curtain and an MFU 011-155 two photocells are positioned to scan across a conveyor, to detect loaded pallets prior to the load interrupting the light curtain. The photocells are positioned to scan across a conveyor, to detect loaded pallets prior to the load interrupting the light curtain.
Type 109-006 photocells have a maximum sensing range of 10 metres. Each transmitter and receiver comes complete with a 1.5m cable.
Sensing Distance | 10m |
---|---|
Transmitter Diode | Infrared |
Sensing Adjustment | None |
Protection Rating | IP65 |
Operating Voltage | 12-240V dc, 24-240V ac - 50/60Hz |
Output | Relay |
Current Consumption | 2VA max |
Response Time | 15ms |
Enclosure | Intensive ABS |
Cable | 1.5m length |
Operating Temp | -20°C to +60°C |
Humidity | 35% to 85% |
Note: Each sensor kit contains 1 x Transmitter unit , 1 x Receiver unit, Mounting brackets.