8000 Plus Series
Specifications
Number of beams | 2 - 48 |
---|---|
Object detection capability | 30mm, 40mm plus 2, 3 and 4 beam perimeter systems |
Detection zone | 330 - 1240mm |
Range | 0.5 - 40m (model dependent) Cross-beam muting 1.25 - 3.5m Parallel-beam muting 0.5 - 3.5m |
Light type | Infrared 880nm |
Response time | 40ms |
Operating temperature | 0 °C to +50 °C |
Enclosure rating | IP66 |
Enclosure | (H x W x D) H x 50 x 57mm |
Status indicators | Status & Diagnostic LEDs |
Status indication | Transmitter (TX) F9 Yellow LED on (flashing) = TX ok Receiver (RX) F10 Green LED on = Guard clear F11 Yellow LED on = Mute 1 clear F12 Yellow LED on = Mute 2 clear F13 Red LED on = Guard blocked F14 Green LED on = Safety outputs on F15 Red LED on = Safety outputs off F16 Yellow LED on = Status relay off F17 Yellow LED on = Mute on F18 Yellow LED flashing = Guard ok F19 Red LED on = Guard blocked, flashing = Fault, F20 Green LED on = Guard ok |
Power supply requirement | 24V DC 2A ± 10% |
Current consumption | 750mA |
Connection | Circular, bayonet locking IP68 |
Classification | BS EN 61496-1, BS IEC 61496-2 Type 2, EN ISO 13849 PL d, EN62061 SIL 2 |
Warranty | 1 Year |
External Device Monitoring(EDM) | +24V DC = on |
Activate | Combined restart and override. On = +24V DC |
Muting | Two circular, bayonet locking connectors. One for each independent muting channel, Mute 1 (M1) and M |
Mute enable | 3rd mute channel. On = +24V DC |
Mode select | Cross-beam mute. On = 0V DCParallel-beam mute. On = +24V DC |
Safety outputs | 2 x N/O fail-safe switching contacts (OSSD 1 & OSSD 2), each rated at 110V, 2A. |
Mute output | Relay output. 0V DC = Mute on |
Product Conformity | The 8000 Plus series has passed Type Examination from European Notified Body, SAFENET to the Machinery Directive. Certification provides users with an assurance that the 8000 Plus series system meets all relevant legislative safety requirements. Together with our ISO 9001:2008 certification full confidence can be placed in the quality, reliability and above all the safety of Smartscan equipment. |